search-loading

Dampers, VAV


How much air do you need?

Ventilation and air conditioning systems are called upon to adjust indoor air quality and the conditions for the right indoor climate.To maintain the necessary air quality and enable economical operation of the system, all air flows of a system must be monitored and controlled. The air-distribution equipment is thus given an important task. TROX Auranor has been a leading supplier of regulating dampers and VAV components in Scandinavia for 25 years, and will continue to develop and supply the market with the latest in design and innovative solutions for VAV systems.

DRS/DRS-T

Commissioning damper / shut off damper for ducts. Class 0 / 4 for minimum leakage trough damper in closed position. Variety of Belimo 24V or 230V actuator is offered.
more details

EPS

EPS liten
The EPS is a circular throttle damper.
Can be used to improve and to complete the existing ventilation system.
more details

Rego-T

Rego-T comes with C-clip connection to ductwork as standard . Frame and leafs made from rollformed galvanized sheet metal. Rego-T is manually operated.
more details

Leo VAV

Leo_1
Circular vav controller for Ø100-630mm.
Airtight shut-off.
Flow rate control in duct, or room pressure control.
Electronic control components, and PC based service and commissioning program.
Optional with acoustical cladding i order to reduce case radiated noise.
Silencer LEV in 500-1000mm lengths with same free area as LeoVAV.
more details

RN

The RN volume flow rate controller operates without any external energy. An easy-moving control damper is displaced by aerodynamic forces such as to maintain a constant set
volume flow throughout the entire differential pressure range. The volume flows are set with the
external pointer by reference to a scale. To simplify applications in individual projects, the controllers can be ordered and installed according to the required size. The desired value is then set simply and reliably when installing the controller. The controllers are also available with type RND acoustic cladding, in order to reduce case-radiated noise.
more details

TSK

TSK
TSK is mainly used in rectangular ventilation ducts for shut-off,
volume flow and pressure control. The damper meets the requirements
for air permeability class 3.
TSK is delivered as a 50mm width and height module as standard,
and is equipped with guide spigot.
Actuator is available as accessory.
On request, the damper can be supplied with a flange spigot or
adapted to fit circular ducts. The damper is also available in air
permeability class 4.
Max. dimensions, complete damper unit: W=2600 x H=2000
The damper’s operating temperature is 100°C max.
more details

News

Fair 2012

Visit us at VVS Dagene 2012 in Lilleström 17.- 19. October.
News

References

Post-Tower, Bonn

Decentralised underfloor ventilation units are the ideal solution for the room-high, glazed facade and they bring considerable benefits in terms of cost.
Reference

Contact

TROX Auranor Norge AS

PO-Box 100
NO-2712 Brandbu
Ph. +47 61 31 35 00
Contact and locations