Fire Dampers, angular

TROX provides the right fire damper for every installation situation


Application Fire Dampers, angular

Fire dampers are designed for automatic isolation of fire compartments in ventilation and air conditioning systems (RLT-systems).
Fire dampers have to close after a certain temperature is reached, sealing off sections of a building to prevent the spreading of fire and smoke.
To prevent smoke from spreading at temperatures below the temperature that triggers the thermal release, fire dampers can also be closed by optional smoke detectors.

Types FK-K90

  • Rectangular fire damper
  • General building inspectorate licence
    Z-41.3-321
  • Reduced differential pressure and sound power level
  • Dry mortarless installation with installation kit
  • Remote controlled with spring return actuator
  • Integration into the centralised BMS with TROXNETCOM

flere detaljer

square, rectangular

W: 200 – 1,500 mm
H: 200 – 800 mm
Intermediate sizes in 1-mm increments
Fire resistance class:
K90 acc. to DIN 4102

Type FKS-EU

  • Rectangular fire damper
  • General building inspectorate licence
    Z-41.3-653
  • Reduced differential pressure and sound power level
  • Dry mortarless installation with installation block
  • Mortar based installation with a perimeter mortar infill, also in lightweight partition walls
  • Remotely controlled with spring return actuator
  • Integration into the centralised BMS with TROXNETCOM

flere detaljer

square, rectangular

W: 200 – 800 mm, intermed. sizes in 50-mm increments
H: 100 – 200 mm
Fire resistance class:
K90 acc. to DIN 4102

Type KU-K30

  • Rectangular fire damper in conjunction with air terminal devices
  • General building inspectorate licence
    Z-41.3.320
  • Reduced differential pressure and sound power level
  • Installation in stand-alone fire-resistant suspended F30 ceilings
  • Design with 24 V or 230 V spring return actuator
  • Control by means of smoke detectors or central fire alarm systems
  • Integration into the centralised BMS with TROXNETCOM

flere detaljer

square

 300 – 625 mm
Fire resistance class:
K30-U acc. to DIN 4102

Type E01-K90

  • Rectangular fire damper
  • General building inspectorate licence
    Z-41.3-323
  • Reduced differential pressure and sound power level
  • Remotely controlled with spring return actuator
  • Integration into the centralised BMS with TROXNETCOM

flere detaljer

square, rectangular

W: Approx. 300 – 1,500 mm
H: Approx. 300 – 800 mm
Fire resistance class:
K90 acc. to DIN 4102

Installation examples